National Repository of Grey Literature 4 records found  Search took 0.00 seconds. 
Residual current device behavior under switching of non-sinusoidal residual currents
Horký, Jakub ; Dostál, Lukáš (referee) ; Valenta, Jiří (advisor)
This bachelor deals with behaviour of a residual-current device during disconnection non-sinusoidal residual current. In the first, theoretical part, basic characteristics and properties of electrical devices are described. Attention is devoted to residual-current device, its structural part, parameters and types. Afterwards, there are described normative requirements of the residual-current device type A in the course of tests. The second part is a practical part. The residual-current device is subjected to residual currents with direct current components (according to the standard), thereby it is checked if it works correctly, it means, if the device is capable of being cut off, At the end of the bachelor, where is a sample laboratory task that demonstrates a check the behavior of the residual-current device at switching off the non-sinusoidal current.
Mathematical model of RCCB sensitive to pulsating direct currents
Kaser, Jakub ; Dostál, Lukáš (referee) ; Valenta, Jiří (advisor)
This Thesis deals with problematics of residual current circuit breaker and its eventual operation malfunction due to DC components. There are magnetic phenomena described in details which occur inside of the apparatus. Consequently, there is proposed a mathematical model of the circuit breaker in Simulink program. The comparison of B-H curves of transformer core is composed and achieved results are incorporated into the proposed model in order to verify a correct operation of the circuit breaker and its reaction to different conditions. The verification of the symmetry of the magnetic field in residual current circuit breaker in Ansys Maxwell program is also a part of the study.
Mathematical model of RCCB sensitive to pulsating direct currents
Kaser, Jakub ; Dostál, Lukáš (referee) ; Valenta, Jiří (advisor)
This Thesis deals with problematics of residual current circuit breaker and its eventual operation malfunction due to DC components. There are magnetic phenomena described in details which occur inside of the apparatus. Consequently, there is proposed a mathematical model of the circuit breaker in Simulink program. The comparison of B-H curves of transformer core is composed and achieved results are incorporated into the proposed model in order to verify a correct operation of the circuit breaker and its reaction to different conditions. The verification of the symmetry of the magnetic field in residual current circuit breaker in Ansys Maxwell program is also a part of the study.
Residual current device behavior under switching of non-sinusoidal residual currents
Horký, Jakub ; Dostál, Lukáš (referee) ; Valenta, Jiří (advisor)
This bachelor deals with behaviour of a residual-current device during disconnection non-sinusoidal residual current. In the first, theoretical part, basic characteristics and properties of electrical devices are described. Attention is devoted to residual-current device, its structural part, parameters and types. Afterwards, there are described normative requirements of the residual-current device type A in the course of tests. The second part is a practical part. The residual-current device is subjected to residual currents with direct current components (according to the standard), thereby it is checked if it works correctly, it means, if the device is capable of being cut off, At the end of the bachelor, where is a sample laboratory task that demonstrates a check the behavior of the residual-current device at switching off the non-sinusoidal current.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.